-- Network Working Group T. Brown
-- Request for Comments: 1595 K. Tesink
-- Category: Standards Track Editors
-- Bell Communications Research
-- March 1994
--
--
-- Definitions of Managed Objects
-- for the SONET/SDH Interface Type
--SONET-MIB DEFINITIONS::=BEGIN
IMPORTSMODULE-IDENTITY,OBJECT-TYPE,Counter32,Gauge32,Integer32,FROM SNMPv2-SMI
TEXTUAL-CONVENTION,DisplayStringFROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUPFROM SNMPv2-CONF
ifIndex, transmission
FROM RFC-1213;-- This is the MIB module for the SMDS Interface objects.sonetMIB MODULE-IDENTITYLAST-UPDATED"9401030000Z"ORGANIZATION"IETF AToM MIB Working Group"CONTACT-INFO" Tracy Brown
Postal: Bell Communications Research
331 Newman Springs Road
P.O. Box 7020
Red Bank, NJ 07701-7020
US
Tel: +1 908 758 2107
Fax: +1 908 758 4177
E-mail: tacox@mail.bellcore.com
Kaj Tesink
Postal: Bell Communications Research
331 Newman Springs Road
P.O. Box 7020
Red Bank, NJ 07701-7020
US
Tel: +1 908 758 5254
Fax: +1 908 758 4196
E-mail: kaj@cc.bellcore.com"DESCRIPTION"The MIB module to describe
SONET/SDH interfaces objects."::={ transmission 39}-- This is the MIB module for the SONET/SDH objectssonetObjects OBJECTIDENTIFIER::={ sonetMIB 1}sonetObjectsPath OBJECTIDENTIFIER::={ sonetMIB 2}sonetObjectsVT OBJECTIDENTIFIER::={ sonetMIB 3}
-- groups in the SONET/SDH MIB modulesonetMedium OBJECTIDENTIFIER::={ sonetObjects 1}sonetSection OBJECTIDENTIFIER::={ sonetObjects 2}sonetLine OBJECTIDENTIFIER::={ sonetObjects 3}sonetFarEndLine OBJECTIDENTIFIER::={ sonetObjects 4}sonetPath OBJECTIDENTIFIER::={ sonetObjectsPath 1}sonetFarEndPath OBJECTIDENTIFIER::={ sonetObjectsPath 2}sonetVT OBJECTIDENTIFIER::={ sonetObjectsVT 1}
sonetFarEndVT OBJECTIDENTIFIER::={ sonetObjectsVT 2}-- the SONET/SDH Medium group-- SONET/SDH interfaces for some applications may be-- electrical interfaces and not optical interfaces.-- This group handles the configuration information for-- both optical SONET/SDH interfaces and electrical-- SONET/SDH interfaces.sonetMediumTable OBJECT-TYPESYNTAXSEQUENCEOF SonetMediumEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Medium table."::={ sonetMedium 1}sonetMediumEntry OBJECT-TYPESYNTAX SonetMediumEntry
MAX-ACCESSnot-accessible
STATUScurrentDESCRIPTION"An entry in the SONET/SDH Medium table."INDEX{ ifIndex }::={ sonetMediumTable 1}
SonetMediumEntry ::=SEQUENCE{
sonetMediumType INTEGER,
sonetMediumTimeElapsed Integer32,
sonetMediumValidIntervals Integer32,
sonetMediumLineCoding INTEGER,
sonetMediumLineType INTEGER,
sonetMediumCircuitIdentifier DisplayString}sonetMediumType OBJECT-TYPESYNTAXINTEGER{sonet(1),sdh(2)
}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable identifies whether a SONET
or a SDH signal is used across this interface."::={ sonetMediumEntry 1}sonetMediumTimeElapsed OBJECT-TYPESYNTAXInteger32(1..900)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of seconds, including partial
seconds, that have elapsed since the beginning of
the current error-measurement period."::={ sonetMediumEntry 2}sonetMediumValidIntervals OBJECT-TYPESYNTAXInteger32(0..96)
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of previous intervals for which valid
data has been stored. A SONET device must support
at least n intervals.
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value of this object will be n unless
the device was brought online within the last
(nx15) minutes, in which case the value will be the
number of complete 15 minute intervals the device has
been online."::={ sonetMediumEntry 3}sonetMediumLineCoding OBJECT-TYPESYNTAXINTEGER{sonetMediumOther(1),sonetMediumB3ZS(2),
sonetMediumCMI(3),sonetMediumNRZ(4),sonetMediumRZ(5)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable describes the line coding for
this interface. The B3ZS and CMI are used for
electrical SONET/SDH signals (STS-1 and STS-3).
The Non-Return to Zero (NRZ) and the Return
to Zero are used for optical SONET/SDH signals."::={ sonetMediumEntry 4}sonetMediumLineType OBJECT-TYPESYNTAXINTEGER{sonetOther(1),sonetShortSingleMode(2),sonetLongSingleMode(3),
sonetMultiMode(4),sonetCoax(5),sonetUTP(6)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable describes the line type for
this interface. The line types are
Short and Long Range
Single Mode fiber or Multi-Mode fiber interfaces,
and coax and UTP for electrical interfaces. The
value sonetOther should be used when the Line Type is
not one of the listed values."::={ sonetMediumEntry 5}sonetMediumCircuitIdentifier OBJECT-TYPESYNTAXDisplayString(SIZE(0..255))
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable contains the transmission
vendor's circuit identifier, for the
purpose of facilitating troubleshooting."::={ sonetMediumEntry 6}-- the SONET/SDH Section group-- this group consists of 2 tables:-- - the SONET/SDH Section Current Table-- - the SONET/SDH Section Interval Table-- the SONET/SDH Section Current Table-- The SONET/SDH Section-- current table contains various statistics-- being collected for the current 15 minute interval.sonetSectionCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetSectionCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION
"The SONET/SDH Section Current table."::={ sonetSection 1}sonetSectionCurrentEntry OBJECT-TYPESYNTAX SonetSectionCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Section Current table."INDEX{ ifIndex }::={ sonetSectionCurrentTable 1}
SonetSectionCurrentEntry ::=SEQUENCE{
sonetSectionCurrentStatus Integer32,
sonetSectionCurrentESs Gauge32,
sonetSectionCurrentSESs Gauge32,
sonetSectionCurrentSEFSs Gauge32,
sonetSectionCurrentCVs Gauge32}
sonetSectionCurrentStatus OBJECT-TYPESYNTAXInteger32(1..6)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetSectionCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetSectionNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetSectionNoDefect
2 sonetSectionLOS
4 sonetSectionLOF"::={ sonetSectionCurrentEntry 1}sonetSectionCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Section in the current 15 minute interval."::={ sonetSectionCurrentEntry 2}sonetSectionCurrentSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Section in the current 15
minute interval."::={ sonetSectionCurrentEntry 3}sonetSectionCurrentSEFSs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Framing Seconds
encountered by a SONET/SDH Section in the current
15 minute interval."::={ sonetSectionCurrentEntry 4}sonetSectionCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Section in the current 15 minute interval."::={ sonetSectionCurrentEntry 5}-- the SONET/SDH Section Interval Table-- The SONET/SDH Section Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at
-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetSectionIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetSectionIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Section Interval table."::={ sonetSection 2}sonetSectionIntervalEntry OBJECT-TYPESYNTAX SonetSectionIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Section Interval table."INDEX{ ifIndex,
sonetSectionIntervalNumber }::={ sonetSectionIntervalTable 1}
SonetSectionIntervalEntry ::=SEQUENCE{
sonetSectionIntervalNumber Integer32,
sonetSectionIntervalESs Gauge32,
sonetSectionIntervalSESs Gauge32,
sonetSectionIntervalSEFSs Gauge32,
sonetSectionIntervalCVs Gauge32}sonetSectionIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetSectionIntervalEntry 1}sonetSectionIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."::={ sonetSectionIntervalEntry 2}sonetSectionIntervalSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."
::={ sonetSectionIntervalEntry 3}sonetSectionIntervalSEFSs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Framing Seconds
encountered by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."::={ sonetSectionIntervalEntry 4}sonetSectionIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Section in a particular 15-minute interval
in the past 24 hours."
::={ sonetSectionIntervalEntry 5}-- the SONET/SDH Line group-- this group consists of 2 tables:-- - the SONET/SDH Line Current Table-- - the SONET/SDH Line Interval Table-- the SONET/SDH Line Current Table-- The SONET/SDH Line-- current table contains various statistics-- being collected for the current 15 minute interval.sonetLineCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Line Current table."::={ sonetLine 1}sonetLineCurrentEntry OBJECT-TYPESYNTAX SonetLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"An entry in the SONET/SDH Line Current table."INDEX{ ifIndex }::={ sonetLineCurrentTable 1}
SonetLineCurrentEntry ::=SEQUENCE{
sonetLineCurrentStatus Integer32,
sonetLineCurrentESs Gauge32,
sonetLineCurrentSESs Gauge32,
sonetLineCurrentCVs Gauge32,
sonetLineCurrentUASs Gauge32}sonetLineCurrentStatus OBJECT-TYPESYNTAXInteger32(1..6)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION
"This variable indicates the
status of the interface.
The sonetLineCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetLineNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetLineNoDefect
2 sonetLineAIS
4 sonetLineRDI"::={ sonetLineCurrentEntry 1}sonetLineCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Line in the current 15 minute interval."::={ sonetLineCurrentEntry 2}sonetLineCurrentSESs OBJECT-TYPESYNTAXGauge32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval."::={ sonetLineCurrentEntry 3}sonetLineCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Line in the current 15 minute interval."::={ sonetLineCurrentEntry 4}sonetLineCurrentUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval."::={ sonetLineCurrentEntry 5}-- the SONET/SDH Line Interval Table-- The SONET/SDH Line Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetLineIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION
"The SONET/SDH Line Interval table."::={ sonetLine 2}sonetLineIntervalEntry OBJECT-TYPESYNTAX SonetLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Line Interval table."INDEX{ ifIndex,
sonetLineIntervalNumber }::={ sonetLineIntervalTable 1}
SonetLineIntervalEntry ::=SEQUENCE{
sonetLineIntervalNumber Integer32,
sonetLineIntervalESs Gauge32,
sonetLineIntervalSESs Gauge32,
sonetLineIntervalCVs Gauge32,
sonetLineIntervalUASs Gauge32
}sonetLineIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetLineIntervalEntry 1}sonetLineIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 2}sonetLineIntervalSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 3}sonetLineIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 4}sonetLineIntervalUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the
number of Unavailable Seconds
encountered by a SONET/SDH Line in
a particular 15-minute interval
in the past 24 hours."::={ sonetLineIntervalEntry 5}-- The SONET/SDH Far End Line group.-- This group may only be implemented by SONET/SDH (LTEs)-- systems that provide for a far end block error (FEBE)-- information at the SONET/SDH Line Layer.-- This group consists of two tables:-- SONET/SDH Far End Line Current Table-- SONET/SDH Far End Line Interval Table
-- The SONET/SDH Far End Line Current Table-- The SONET/SDH Far End Line Current table contains-- various statistics being-- collected for the current 15 minute interval.-- The statistics are collected from the far end-- block error code (FEBE)-- within the third Z2 byte of the Line Overhead-- in Broadband ISDN applications.-- The definitions are the same as described for-- the near-end information.sonetFarEndLineCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End Line Current table."::={ sonetFarEndLine 1}sonetFarEndLineCurrentEntry OBJECT-TYPESYNTAX SonetFarEndLineCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far End Line Current table."INDEX{ ifIndex }::={ sonetFarEndLineCurrentTable 1}
SonetFarEndLineCurrentEntry ::=SEQUENCE{
sonetFarEndLineCurrentESs Gauge32,
sonetFarEndLineCurrentSESs Gauge32,
sonetFarEndLineCurrentCVs Gauge32,
sonetFarEndLineCurrentUASs Gauge32}sonetFarEndLineCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Far
Far End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."::={ sonetFarEndLineCurrentEntry 1}sonetFarEndLineCurrentSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Medium/Section/Line
interface in the current 15 minute
interval."::={ sonetFarEndLineCurrentEntry 2}sonetFarEndLineCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Medium/Section/Line
interface in the current 15 minute interval."::={ sonetFarEndLineCurrentEntry 3}sonetFarEndLineCurrentUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Medium/Section/Line
interface in the current 15 minute interval."::={ sonetFarEndLineCurrentEntry 4}-- The SONET/SDH Far End Line Interval Table-- The SONET/SDH Far End Line Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetFarEndLineIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End Line Interval table."::={ sonetFarEndLine 2}sonetFarEndLineIntervalEntry OBJECT-TYPESYNTAX SonetFarEndLineIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far
End Line Interval table."INDEX{ ifIndex,
sonetFarEndLineIntervalNumber }
::={ sonetFarEndLineIntervalTable 1}
SonetFarEndLineIntervalEntry ::=SEQUENCE{
sonetFarEndLineIntervalNumber Integer32,
sonetFarEndLineIntervalESs Gauge32,
sonetFarEndLineIntervalSESs Gauge32,
sonetFarEndLineIntervalCVs Gauge32,
sonetFarEndLineIntervalUASs Gauge32}sonetFarEndLineIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetFarEndLineIntervalEntry 1}sonetFarEndLineIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 2}sonetFarEndLineIntervalSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 3}sonetFarEndLineIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 4}sonetFarEndLineIntervalUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Line
interface in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndLineIntervalEntry 5}-- the SONET/SDH Path group-- this group consists of 2 tables:-- - the SONET/SDH Path Current Table-- - the SONET/SDH Path Interval Table-- the SONET/SDH Path Current Table-- The SONET/SDH Path-- current table contains various statistics-- being collected for the current 15 minute interval.sonetPathCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Path Current table."
::={ sonetPath 1}sonetPathCurrentEntry OBJECT-TYPESYNTAX SonetPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Path Current table."INDEX{ ifIndex }::={ sonetPathCurrentTable 1}
SonetPathCurrentEntry ::=SEQUENCE{
sonetPathCurrentWidth INTEGER,
sonetPathCurrentStatus Integer32,
sonetPathCurrentESs Gauge32,
sonetPathCurrentSESs Gauge32,
sonetPathCurrentCVs Gauge32,
sonetPathCurrentUASs Gauge32}
sonetPathCurrentWidth OBJECT-TYPESYNTAXINTEGER{sts1(1),sts3cSTM1(2),sts12cSTM4(3),sts24c(4),sts48cSTM16(5)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"A value that indicates the type of the SONET/SDH
Path. For SONET, the assigned types are
the STS-Nc SPEs, where N = 1, 3, 12, 24, and 48.
STS-1 is equal to 51.84 Mbps. For SDH, the assigned
types are the STM-Nc VCs, where N = 1, 4, and 16."::={ sonetPathCurrentEntry 1}sonetPathCurrentStatus OBJECT-TYPE
SYNTAXInteger32(1..14)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetPathCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetPathNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetPathNoDefect
2 sonetPathSTSLOP
4 sonetPathSTSAIS
8 sonetPathSTSRDI
16 sonetPathUnequipped
32 sonetPathSignalLabelMismatch"::={ sonetPathCurrentEntry 2}sonetPathCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Path in the current 15 minute interval."::={ sonetPathCurrentEntry 3}sonetPathCurrentSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Path in the current 15
minute
interval."::={ sonetPathCurrentEntry 4}sonetPathCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Path in the current 15 minute interval."::={ sonetPathCurrentEntry 5}sonetPathCurrentUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a Path in the current
15 minute, interval."::={ sonetPathCurrentEntry 6}-- the SONET/SDH Path Interval Table-- The SONET/SDH Path Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at
-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetPathIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Path Interval table."::={ sonetPath 2}sonetPathIntervalEntry OBJECT-TYPESYNTAX SonetPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Path Interval table."INDEX{ ifIndex,
sonetPathIntervalNumber }::={ sonetPathIntervalTable 1}
SonetPathIntervalEntry ::=
SEQUENCE{
sonetPathIntervalNumber Integer32,
sonetPathIntervalESs Gauge32,
sonetPathIntervalSESs Gauge32,
sonetPathIntervalCVs Gauge32,
sonetPathIntervalUASs Gauge32}sonetPathIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."
::={ sonetPathIntervalEntry 1}sonetPathIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Path in a
particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 2}sonetPathIntervalSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Path in
a particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 3}
sonetPathIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Path in a particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 4}sonetPathIntervalUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a Path in a
particular 15-minute interval
in the past 24 hours."::={ sonetPathIntervalEntry 5}-- The SONET/SDH Far End Path group-- This group consists of two tables:-- - SONET/SDH Far End Path Current Table-- - SONET/SDH Far End Path Interval Table-- The SONET/SDH Far End Path Current Table-- The SONET/SDH Far End Path Current table-- contains various statistics-- being collected for the current 15 minute interval.-- The statistics are collected from-- the far end block error code-- (FEBE) within the G1 byte of the Path Overhead.-- The definitions are the same as described for-- the near-end information.sonetFarEndPathCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End Path Current table."::={ sonetFarEndPath 1}
sonetFarEndPathCurrentEntry OBJECT-TYPESYNTAX SonetFarEndPathCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far End Path Current table."INDEX{ ifIndex }::={ sonetFarEndPathCurrentTable 1}
SonetFarEndPathCurrentEntry ::=SEQUENCE{
sonetFarEndPathCurrentESs Gauge32,
sonetFarEndPathCurrentSESs Gauge32,
sonetFarEndPathCurrentCVs Gauge32,
sonetFarEndPathCurrentUASs Gauge32}sonetFarEndPathCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"The counter associated with the number of Far
Far End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."::={ sonetFarEndPathCurrentEntry 1}sonetFarEndPathCurrentSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Path
interface in the current 15 minute
interval."::={ sonetFarEndPathCurrentEntry 2}sonetFarEndPathCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Path interface in
the current 15 minute interval."::={ sonetFarEndPathCurrentEntry 3}sonetFarEndPathCurrentUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Path interface in
the current 15 minute interval."::={ sonetFarEndPathCurrentEntry 4}-- The SONET/SDH Far End Path Interval Table-- The SONET/SDH Far End Path Interval Table-- contains various statistics
-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetFarEndPathIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End Path Interval table."::={ sonetFarEndPath 2}sonetFarEndPathIntervalEntry OBJECT-TYPESYNTAX SonetFarEndPathIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far
End Path Interval table."INDEX{ ifIndex,
sonetFarEndPathIntervalNumber }::={ sonetFarEndPathIntervalTable 1}
SonetFarEndPathIntervalEntry ::=SEQUENCE{
sonetFarEndPathIntervalNumber Integer32,
sonetFarEndPathIntervalESs Gauge32,
sonetFarEndPathIntervalSESs Gauge32,
sonetFarEndPathIntervalCVs Gauge32,
sonetFarEndPathIntervalUASs Gauge32}sonetFarEndPathIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetFarEndPathIntervalEntry 1}sonetFarEndPathIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH Path interface in a
particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 2}sonetFarEndPathIntervalSESs OBJECT-TYPESYNTAXGauge32
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH Path interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 3}sonetFarEndPathIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH Path interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 4}sonetFarEndPathIntervalUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH Path interface in
a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndPathIntervalEntry 5}-- the SONET/SDH Virtual Tributary group-- this group consists of 2 tables:-- - the SONET/SDH VT Current Table-- - the SONET/SDH VT Interval Table-- For SDH signals, virtual tributaries are-- called VCs instead of VTs-- A VT1.5 = VC11-- A VT2 = VC12-- A VT3 = none-- A VT6 = VC3-- the SONET/SDH VT Current Table-- The SONET/SDH VT current table-- contains various statistics
-- being collected for the-- current 15 minute interval.sonetVTCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetVTCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH VT Current table."::={ sonetVT 1}sonetVTCurrentEntry OBJECT-TYPESYNTAX SonetVTCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH VT Current table."INDEX{ ifIndex }::={ sonetVTCurrentTable 1}
SonetVTCurrentEntry ::=SEQUENCE{
sonetVTCurrentWidth INTEGER,
sonetVTCurrentStatus Integer32,
sonetVTCurrentESs Gauge32,
sonetVTCurrentSESs Gauge32,
sonetVTCurrentCVs Gauge32,
sonetVTCurrentUASs Gauge32}sonetVTCurrentWidth OBJECT-TYPESYNTAXINTEGER{vtWidth15VC11(1),vtWidth2VC12(2),vtWidth3(3),vtWidth6VC2(4),vtWidth6c(5)}MAX-ACCESSread-write
STATUScurrentDESCRIPTION"A value that indicates the type of the SONET
VT and SDH VC. Assigned widths are
VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."::={ sonetVTCurrentEntry 1}sonetVTCurrentStatus OBJECT-TYPESYNTAXInteger32(1..30)MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"This variable indicates the
status of the interface.
The sonetVTCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
and failures
simultaneously.
The sonetVTNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetVTNoDefect
2 sonetVTLOP
4 sonetVTPathAIS
8 sonetVTPathRDI
16 sonetVTPathRFI
32 sonetVTUnequipped
64 sonetVTSignalLabelMismatch"::={ sonetVTCurrentEntry 2}sonetVTCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
VT in the current 15 minute interval."::={ sonetVTCurrentEntry 3}sonetVTCurrentSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH VT in the current 15 minute
interval."
::={ sonetVTCurrentEntry 4}sonetVTCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH VT in the current 15 minute interval."::={ sonetVTCurrentEntry 5}sonetVTCurrentUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a VT in the current
15 minute, interval."::={ sonetVTCurrentEntry 6}-- the SONET/SDH VT Interval Table
-- The SONET/SDH VT Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetVTIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH VT Interval table."::={ sonetVT 2}sonetVTIntervalEntry OBJECT-TYPESYNTAX SonetVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"An entry in the SONET/SDH VT Interval table."INDEX{ ifIndex,
sonetVTIntervalNumber }::={ sonetVTIntervalTable 1}
SonetVTIntervalEntry ::=SEQUENCE{
sonetVTIntervalNumber Integer32,
sonetVTIntervalESs Gauge32,
sonetVTIntervalSESs Gauge32,
sonetVTIntervalCVs Gauge32,
sonetVTIntervalUASs Gauge32}sonetVTIntervalNumber OBJECT-TYPESYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrent
DESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetVTIntervalEntry 1}sonetVTIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH VT in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 2}sonetVTIntervalSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-only
STATUScurrentDESCRIPTION"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH VT
in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 3}sonetVTIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH VT in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 4}sonetVTIntervalUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The counter associated with the number of
Unavailable Seconds
encountered by a VT in a particular 15-minute interval
in the past 24 hours."::={ sonetVTIntervalEntry 5}-- The SONET/SDH Far End VT group-- This group consists of two tables:-- SONET/SDH Far End VT Current Table-- SONET/SDH Far End VT Interval Table-- The SONET/SDH Far End VT Current-- The SONET/SDH Far End VT Current table-- contains various statistics-- being collected for the current 15 minute interval.-- The statistics are collected from-- the far end block error code-- (FEBE) within the G1 byte of the VT Overhead.-- The definitions are the same as described for-- the near-end information.sonetFarEndVTCurrentTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndVTCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End VT Current table."::={ sonetFarEndVT 1}sonetFarEndVTCurrentEntry OBJECT-TYPESYNTAX SonetFarEndVTCurrentEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far End VT Current table."INDEX{ ifIndex }::={ sonetFarEndVTCurrentTable 1}
SonetFarEndVTCurrentEntry ::=SEQUENCE{
sonetFarEndVTCurrentESs Gauge32,
sonetFarEndVTCurrentSESs Gauge32,
sonetFarEndVTCurrentCVs Gauge32,
sonetFarEndVTCurrentUASs Gauge32}sonetFarEndVTCurrentESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of Far
Far End Errored Seconds encountered by a SONET/SDH
interface in the current 15 minute interval."::={ sonetFarEndVTCurrentEntry 1}sonetFarEndVTCurrentSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH VT interface
in the current 15 minute
interval."
::={ sonetFarEndVTCurrentEntry 2}sonetFarEndVTCurrentCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH VT interface
in the current 15 minute interval."::={ sonetFarEndVTCurrentEntry 3}sonetFarEndVTCurrentUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH VT interface
in the current 15 minute interval."::={ sonetFarEndVTCurrentEntry 4}-- The SONET/SDH Far End VT Interval Table-- The SONET/SDH Far End VT Interval Table-- contains various statistics-- collected by each system over a maximum-- of the previous 24 hours of-- operation. The past 24 hours may be broken into 96-- completed 15 minute intervals.-- A system is required to store at-- least 4 completed 15 minute interval.-- The default value is 32 intervals.sonetFarEndVTIntervalTable OBJECT-TYPESYNTAXSEQUENCEOF SonetFarEndVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The SONET/SDH Far End VT Interval table."::={ sonetFarEndVT 2}
sonetFarEndVTIntervalEntry OBJECT-TYPESYNTAX SonetFarEndVTIntervalEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the SONET/SDH Far
End VT Interval table."INDEX{ ifIndex,
sonetFarEndVTIntervalNumber }::={ sonetFarEndVTIntervalTable 1}
SonetFarEndVTIntervalEntry ::=SEQUENCE{
sonetFarEndVTIntervalNumber Integer32,
sonetFarEndVTIntervalESs Gauge32,
sonetFarEndVTIntervalSESs Gauge32,
sonetFarEndVTIntervalCVs Gauge32,
sonetFarEndVTIntervalUASs Gauge32}sonetFarEndVTIntervalNumber OBJECT-TYPE
SYNTAXInteger32(1..96)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."::={ sonetFarEndVTIntervalEntry 1}sonetFarEndVTIntervalESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Errored Seconds encountered
by a SONET/SDH VT interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 2}sonetFarEndVTIntervalSESs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Severely Errored Seconds
encountered by a SONET/SDH VT interface
in a particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 3}sonetFarEndVTIntervalCVs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Coding Violations reported via
the far end block error count
encountered by a
SONET/SDH VT interface in a
particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 4}sonetFarEndVTIntervalUASs OBJECT-TYPESYNTAXGauge32MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The counter associated with the number of
Far End Unavailable Seconds
encountered by a
SONET/SDH VT interface in a
particular 15-minute interval
in the past 24 hours."::={ sonetFarEndVTIntervalEntry 5}-- conformance informationsonetConformance OBJECTIDENTIFIER::={ sonetMIB 4}sonetGroups OBJECTIDENTIFIER::={ sonetConformance 1}
sonetCompliances OBJECTIDENTIFIER::={ sonetConformance 2}-- compliance statementssonetCompliance MODULE-COMPLIANCESTATUScurrentDESCRIPTION"The compliance statement for SONET/SDH
interfaces."MODULE-- this moduleMANDATORY-GROUPS{ sonetMediumStuff, sonetSectionStuff }GROUP sonetLineStuff
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries."GROUP sonetFarEndLineStuff
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH Lines,
Paths or Virtual Tributaries, and that
provide for a far end block error (FEBE)
information at the SONET/SDH Line Layer."GROUP sonetPathStuff
DESCRIPTION"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual
Tributaries."--PSIM OBJECT sonetPathWidthOBJECT sonetPathCurrentWidth
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."GROUP sonetFarEndPathStuff
DESCRIPTION"Implementation of this group is optional for all
SONET/SDH systems that terminate SONET/SDH
Paths or Virtual
Tributaries, and that process
Far End information."GROUP sonetVTStuff
DESCRIPTION
"Implementation of this group is mandatory for all
SONET/SDH systems that terminate SONET/SDH
Virtual Tributaries."--PSIM OBJECT sonetVTWidthOBJECT sonetVTCurrentWidth
MIN-ACCESSread-onlyDESCRIPTION"Write access is not required."GROUP sonetFarEndVTStuff
DESCRIPTION"Implementation of this group is optional for
all SONET/SDH systems that terminate the
SONET/SDH floating Virtual Tributaries, and
that process Far End information."::={ sonetCompliances 1}-- units of conformancesonetMediumStuff OBJECT-GROUPOBJECTS{ sonetMediumType,
sonetMediumTimeElapsed,
sonetMediumValidIntervals,
sonetMediumLineCoding,
sonetMediumLineType,
sonetMediumCircuitIdentifier }STATUScurrentDESCRIPTION"A collection of objects providing configuration
information applicable to all SONET/SDH
interfaces."::={ sonetGroups 1}sonetSectionStuff OBJECT-GROUPOBJECTS{ sonetSectionCurrentStatus,
sonetSectionCurrentESs,
sonetSectionCurrentSESs,
sonetSectionCurrentSEFSs,
sonetSectionCurrentCVs,
sonetSectionIntervalESs,
sonetSectionIntervalSESs,
sonetSectionIntervalSEFSs,
sonetSectionIntervalCVs
}STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Section interfaces."::={ sonetGroups 2}sonetLineStuff OBJECT-GROUPOBJECTS{ sonetLineCurrentStatus,
sonetLineCurrentESs,
sonetLineCurrentSESs,
sonetLineCurrentCVs,
sonetLineCurrentUASs,
sonetLineIntervalESs,
sonetLineIntervalSESs,
sonetLineIntervalCVs,
sonetLineIntervalUASs }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Line interfaces."::={ sonetGroups 3}sonetFarEndLineStuff OBJECT-GROUPOBJECTS{ sonetFarEndLineCurrentESs,
sonetFarEndLineCurrentSESs,
sonetFarEndLineCurrentCVs,
sonetFarEndLineCurrentUASs,
sonetFarEndLineIntervalESs,
sonetFarEndLineIntervalSESs,
sonetFarEndLineIntervalCVs,
sonetFarEndLineIntervalUASs }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Line interfaces,
and maintaining Line Far End information."::={ sonetGroups 4}sonetPathStuff OBJECT-GROUPOBJECTS{ sonetPathCurrentWidth,
sonetPathCurrentStatus,
sonetPathCurrentESs,
sonetPathCurrentSESs,
sonetPathCurrentCVs,
sonetPathCurrentUASs,
sonetPathIntervalESs,
sonetPathIntervalSESs,
sonetPathIntervalCVs,
sonetPathIntervalUASs }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH Path interfaces."::={ sonetGroups 5}sonetFarEndPathStuff OBJECT-GROUPOBJECTS{ sonetFarEndPathCurrentESs,
sonetFarEndPathCurrentSESs,
sonetFarEndPathCurrentCVs,
sonetFarEndPathCurrentUASs,
sonetFarEndPathIntervalESs,
sonetFarEndPathIntervalSESs,
sonetFarEndPathIntervalCVs,
sonetFarEndPathIntervalUASs }STATUScurrent
DESCRIPTION"A collection of objects providing information
specific to SONET/SDH Path interfaces,
and maintaining Path Far End information."::={ sonetGroups 6}sonetVTStuff OBJECT-GROUPOBJECTS{ sonetVTCurrentWidth,
sonetVTCurrentStatus,
sonetVTCurrentESs,
sonetVTCurrentSESs,
sonetVTCurrentCVs,
sonetVTCurrentUASs,
sonetVTIntervalESs,
sonetVTIntervalSESs,
sonetVTIntervalCVs,
sonetVTIntervalUASs }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH VT interfaces."::={ sonetGroups 7}
sonetFarEndVTStuff OBJECT-GROUPOBJECTS{ sonetFarEndVTCurrentESs,
sonetFarEndVTCurrentSESs,
sonetFarEndVTCurrentCVs,
sonetFarEndVTCurrentUASs,
sonetFarEndVTIntervalESs,
sonetFarEndVTIntervalSESs,
sonetFarEndVTIntervalCVs,
sonetFarEndVTIntervalUASs }STATUScurrentDESCRIPTION"A collection of objects providing information
specific to SONET/SDH VT interfaces,